Power UNITS FOR LIFT TABLE

Electrical power UNITS FOR LIFT TABLE 1
General Description
This energy unit is built solely for the little lift table,Consisting of high strain gear pump, AC motor, multi-functional manifold, valves, tank, etc. This energy unit has become widely used during the sector of logistic units for instance minifork lift, scissors lift and ariel functioning platforms. The lower-ing motion is controlled by the solenoid valve using the speed controlled by the adjustable needle valve.
Energy UNITS FOR LIFT TABLE two
Basic Description
This energy unit is designed exclusively for the medium lift table, Consisting of really effecient gear pump, AC motor, multifunctional manifold, valves, tank, ect. The reducing motion is actived through the solenoid valve along with the pace managed by the adjustable needle valve. When the lift rises to a large positoin, but the power provide is cut, the lowering motion is controlled through the manual override function.
Electrical power UNITS FOR LIFT TABLE 3
Basic Description
This energy unit is built solely for your substantial lift table, Consisting of extremely effecient gear pump, AC motor, multi-functional manifold, valves, tank, ect. The lowering motion is actived by the solenoid valve along with the velocity controlled by a pressure compensated flow handle valve.
Energy UNITS FOR LIFT TABLE 4
General Description
This electrical power unit is designed exclusively for your big lift table, Consisting of remarkably effecient gear pump, AC motor, multi-functional manifold, valves, tank, ect. The decreasing movement is actived through the solenoid valve and the pace managed through the adjustable needle valve. When the lift rises to a large positoin, but the energy provide is minimize, the lowering motion is controlled from the guide override function.
Distinctive Notes
one. This power unit is of S3 duty cycle, which could only do the job intermittently and repeatedly, i.e. 1 minute on and 9 minutes off.
2. Clean every one of the hydraulic components concerned just before set up of the power unit.
3. Viscosity in the oil shoud be 15~46 cst,which should also be clean and free of charge of impurities.N46 hydraulic oil is proposed.
4. Oil transforming is required immediately after the initial a hundred operation hours,afterwards the moment each 3000 hours.
5. The energy unit shown is created to be mounted vertically.

Tags

Recent Posts

As one of leading flange coupling manufacturers, suppliers and exporters of mechanical products, We offer flange coupling and many other products.

Please contact us for details.

Mail:[email protected]

Manufacturer supplier exporter of flange coupling