China manufacturer Gfc-20X25 Type Aluminum Alloy Shaft Flange Coupling Flexible Shaft Coupling flange coupling

Product Description

GFC-20×25 Type Aluminum Alloy Shaft Flange Coupling Flexible Shaft Coupling

 

Description of GFC-20×25 Type Aluminum Alloy Shaft Flange Coupling Flexible Shaft Coupling

model parameter common bore diameter d1,d2 ΦD L LF LP F M tightening screw torque
(N.M)
GFC-14X22 3,4,5,6,6.35 14 22 14.3 6.6 5.0 M2.5 1.0
GFC-20×25 3,4,5,6,6.35,7,8,9,9.525,10 20 25 16.7 8.6 5.9 M3 1.5
GFC-20X30 3,4,5,6,6.35,7,8,9,9.525,10 20 30 19.25 8.6 5.9 M3 1.5
GFC-25X30 4,5,6,6.35,7,8,9,9.525,10,11,12 25 30 20.82 11.6 8.5 M4 2.5
GFC-25X34 4,5,6,6.35,7,8,9,9.525,10,11,12 25 34 22.82 11.6 8.5 M4 2.5
GFC-30×35 5,6,6.35,7,8,9,10,11,12,12.7,14,15,16 30 35 23 11.5 10 M4 2.5
GFC-30X40 5,6,6.35,7,8,9,10,11,12,12.7,14,15,16 30 40 25 11.5 10 M4 2.5
GFC-40X50 6,8,9,10,11,12,12.7,14,15,16,17,18,19,20,22,24 40 50 32.1 14.5 14 M5 7
GFC-40X55 6,8,9,10,11,12,12.7,14,15,16,17,18,19,20,22,24 40 55 34.5 14.5 14 M5 7
GFC-40X66 6,8,910,11,12,12.7,14,15,16,17,18,19,20,22,24 40 66 40 14.5 14 M5 7
GFC-55X49 10,11,12,12.7,14,15,16,17,18,19,20,22,24,25,28,30,32 55 49 32 16.1 13.5 M6 12
GFC-55X78 8,10,12,12.7,14,15,16,17,18,19,20,22,24,25,28,30,32 55 78 46.4 16.1 19 M6 12
GFC-65X80 14,15,16,17,18,19,20,22,24,25,28,30,32,35,38,40 65 80 48.5 17.3 14 M8 20
GFC-65X90 14,15,16,17,18,19,20,22,24,25,28,30,32,35,38,40 65 90 53.5 17.3 22.5 M8 20
GFC-80X114 19,20,22,24,25,28,30,32,35,38,40,42,45 80 114 68 22.5 16 M8 20
GFC-95X126 19,20,22,24,25,28,30,32,35,38,40,42,45,50,55 95 126 74.5 24 18 M10 30

 

model parameter Rated torque
(N.M)*
allowable eccentricity
(mm)*
allowable deflection angle
(°)*
allowable axial deviation
(mm)*
maximum speed
rpm
static torsional stiffness
(N.M/rad)
moment of inertia
(Kg.M2)
Material of shaft sleeve Material of shrapnel surface treatment weight
(g)
GFC-14X22 5.0 0.1 1 ±02 10000 50 1.0×10-6 High strength aluminum alloy Polyurethane imported from Germany Anodizing treatment 10
GFC-20X25 5.0 0.1 1 ±02 10000 50 1.0×10-6 15
GFC-20X30 5.0 0.1 1 ^02 10000 53 1.1×10-6 19
GFC-25X30 10 0.1 1   10000 90 5.2X10-6 33
GFC-25X34 10 0.1 1 £)2 10000 90 5.2×10-6 42
GFC-30X35 12.5 0.1 1 ±02 10000 123 6.2×10-6 50
GFC-30×40 12.5 0.1 1 102 10000 123 6.2×10-6 60
GFC-40X50 17 0.1 1   8000 1100 3.8×10-5 115
GFC-40X55 17 0.1 1 ±02 8000 1100 3.8×10-5 127
GFC-40X66 17 0.1 1   7000 1140 3.9×10-5 154
GFC-55X49 45 0.1 1 ±02 6500 2350 1.6×10-3 241
GFC-55X78 45 0.1 1 102 6000 2500 1.6×10-3 341
GFC-65X80 108 0.1 1 ±02 5500 4500 3.8×10-3 433
GFC-65X90 108 0.1 1 ±02 5500 4800 3.8×10-3 583
GFC-80X114 145 0.1 1 £)2 4500 5000 1.8×10-3 1650
GFC-95X126 250 0.1 1 ±02 4000 5000 2.0×10-3 1000

  /* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

flange coupling

Proper Installation and Alignment of Flange Couplings

Installing and aligning a flange coupling properly is crucial to ensure its optimal performance and to prevent premature wear or failure. Here are the steps to follow for a successful installation:

  1. Prepare the Components: Before starting the installation, ensure that all the components, including the flange coupling, shafts, and fasteners, are clean and free from dirt or debris. Inspect the coupling for any visible damage or defects.
  2. Check Shaft Alignment: Verify the alignment of the shafts before installing the flange coupling. Misalignment can lead to increased stresses on the coupling and other connected equipment.
  3. Use Proper Lubrication: Apply the recommended lubricant to the contact surfaces of the flange coupling. Proper lubrication reduces friction and wear, enhancing the coupling’s lifespan.
  4. Align the Flange Coupling: Position the flange coupling between the shafts and ensure that the bolt holes are aligned with the corresponding holes in the shafts.
  5. Insert Fasteners: Insert the bolts or screws through the bolt holes and hand-tighten them. Avoid fully tightening any fasteners at this stage.
  6. Check Runout: Measure the runout of the coupling during rotation to verify that it is within acceptable limits. Excessive runout indicates a misaligned coupling.
  7. Properly Torque Fasteners: Using a torque wrench, tighten the fasteners in a cross-pattern to the manufacturer’s recommended torque values. This ensures even distribution of the load and prevents distortion of the flange coupling.
  8. Recheck Alignment: After torquing the fasteners, recheck the shaft alignment to ensure it has not shifted during the tightening process.
  9. Inspect the Assembly: Conduct a final visual inspection of the installed flange coupling and surrounding components to verify that everything is properly aligned and secured.
  10. Perform Test Run: Run the equipment with the newly installed flange coupling under no-load conditions initially to check for any unusual vibrations or noises.
  11. Monitor Performance: During the initial operation and throughout regular use, monitor the flange coupling’s performance and check for signs of wear, misalignment, or other issues.

Professional Installation: If you are unsure about the installation process or need to install a flange coupling in a complex system, consider seeking assistance from a qualified professional or coupling manufacturer’s technical support team. Proper installation is essential for ensuring the long-term reliability and performance of the flange coupling and the connected equipment.

flange coupling

Key Features to Consider When Purchasing a Flange Coupling

When purchasing a flange coupling, it is essential to consider several key features to ensure it meets the specific requirements of your application. Here are the main factors to look for:

  • Type of Flange Coupling: There are various types of flange couplings, such as rigid, flexible, and fluid couplings. Choose the type that best suits your application’s needs, considering factors like misalignment compensation, torsional stiffness, and vibration damping.
  • Size and Dimensions: Select the flange coupling with the appropriate size and dimensions to fit your shafts and equipment. Consider shaft diameter, coupling length, and any space limitations.
  • Material: Flange couplings can be made from various materials, including steel, aluminum, stainless steel, and elastomers. Choose a material that offers the required strength, corrosion resistance, and durability for your operating conditions.
  • Torsional Rating: Check the torsional rating of the flange coupling to ensure it can handle the torque requirements of your application without failure or deformation.
  • Misalignment Compensation: If your application experiences shaft misalignment, opt for a flexible flange coupling that can accommodate angular, parallel, and axial misalignment to prevent stress on connected equipment.
  • Backlash: For precision applications, select a flange coupling with minimal or no backlash to maintain accurate positioning and reduce the effects of mechanical play.
  • Operating Speed: Consider the operating speed range of the flange coupling to ensure it can handle the rotational speed requirements without issues like resonance or fatigue.
  • Environmental Compatibility: Evaluate the flange coupling’s ability to withstand the environmental conditions of your application, such as temperature, humidity, and exposure to chemicals or corrosive substances.
  • Installation and Maintenance: Choose a flange coupling that is easy to install and maintain, as proper installation and periodic maintenance are crucial for optimal performance and longevity.
  • Cost and Value: Compare the cost of the flange coupling with its features and performance to ensure you are getting the best value for your investment.

By carefully considering these key features, you can select a flange coupling that not only meets the demands of your application but also ensures reliable and efficient power transmission while minimizing downtime and maintenance costs.

flange coupling

Advantages of Flange Couplings in Mechanical Systems

Flange couplings offer several advantages in mechanical systems, making them a popular choice for connecting shafts in various applications:

  • High Torque Transmission: Flange couplings provide a rigid and secure connection between shafts, allowing for efficient transmission of high torque without slippage or power loss.
  • Precise Alignment: Proper alignment of flange couplings ensures that the connected shafts are in perfect axial alignment, reducing the risk of excessive bearing loads and increasing the longevity of the machinery.
  • Zero Backlash: Flange couplings have no play or free movement between the shafts, resulting in immediate torque transmission and precise motion control, especially in applications requiring precise positioning.
  • Robust and Durable: Flange couplings are typically made from high-quality materials such as steel, cast iron, or aluminum, providing excellent durability and resistance to wear and corrosion.
  • Wide Range of Sizes and Torque Capacities: Flange couplings are available in various sizes and configurations, allowing them to be used in a wide range of applications with different torque requirements.
  • Simple Installation: Installing flange couplings is relatively straightforward, requiring alignment and fastening of the flanges with bolts and nuts.
  • Wide Application Range: Flange couplings are used in various industries, including heavy machinery, pumps, compressors, marine propulsion, and power generation equipment.
  • Suitable for High-Speed Applications: Flange couplings can handle high rotational speeds, making them suitable for applications requiring high-speed power transmission.
  • Minimal Maintenance: Once properly installed, flange couplings require minimal maintenance, reducing downtime and operational costs.

Despite their advantages, flange couplings also have some limitations. They lack the ability to compensate for misalignment like flexible couplings, which can lead to increased stress on bearings and other components if not correctly aligned. Additionally, the rigid nature of flange couplings means they may not be suitable for applications where shaft misalignment is common or where shock and vibration absorption is required.

Overall, flange couplings are a reliable and robust choice for mechanical systems, particularly in applications demanding high torque transmission and precise shaft alignment. Proper installation and maintenance are crucial to ensure optimal performance and longevity of both the coupling and the connected machinery.

China manufacturer Gfc-20X25 Type Aluminum Alloy Shaft Flange Coupling Flexible Shaft Coupling  flange couplingChina manufacturer Gfc-20X25 Type Aluminum Alloy Shaft Flange Coupling Flexible Shaft Coupling  flange coupling
editor by CX 2024-03-28

Recent Posts

As one of leading flange coupling manufacturers, suppliers and exporters of mechanical products, We offer flange coupling and many other products.

Please contact us for details.

Mail:[email protected]

Manufacturer supplier exporter of flange coupling